Home
Over ons
Produkten
Downloaden
Technische Lib
Contact
Navraag
Sitemap
Links
 

Alarm & Audio & Elektronische Kabel

Belden gelijkwaardige kabels

Coax Kabels

Control Kabels

Fiber Optic Kabels

Flexibele Kabels

Instrumentatie Kabel

Lan kabels
Energie Kabel
Spoorweg Kabel

Robotica

Rollend materieel kabels
Rubber & Crane kabels
Beveiliging kabels

Telefoonkabels

Luchthaven Kabels

Bus kabels

Kabel Klieren

Data Kabels

Hitte detectie kabels
Hoge temperatuur kabels
Kabels snelweg
Marine, olie-, gas-en petrochemische Kabels
Speciaal Kabels
Spiraal Kabels
Thermokoppel Kabels
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Telefoonkabels

 PVC Insulated Self Supporting Drop Wires to RUS (REA) PE-7

Aanvraag

The drop wires are designed for extending a distribution cable pair from a pole or cable terminal to a subscriber premises. The cables are suitable for aerial installation.

Normen

 

• RUS (REA) PE-7

Bouw

Dirigenten
Solid annealed bare copper 0.64mm or 0.9mm as per ASTM B-3/class 1 of IEC 60228

Steel Bearer Wire
Galvanized steel wire, solid

Isolatie
High density black PVC which can be made ultraviolet resistant by addition of carbon black

Elektrische eigenschappen

Nominal Conductor Diameter

mm

0.64

0.9

Conductor Gauge Size

AWG

22

19

Conductor Size

mm2

0.332

0.636

Maximum Conductor Resistance @20°C

Ω/km/ Ω/mile

57.1/91.8

28/44.9

Minimum Insulation Resistance @500V DC

MΩ.km / MΩ.mile

400/249

400/249

Maximum Breaking Strength

Kg

155

155

Dielectric Strength 1min

V RMS

1500

1500

Nominal Insulation Thickness

mm/inch

1.0/0.039

1.05/0.041

Nominal Insulated Conductor Diameter

mm/inch

2.65/0.104

3.05/0.12

Nominal Diameter of Steel Wire Core

mm/inch

3.2/0.126

3.35/0.132

Mechanical and Thermal Properties

Temperature range during operation (fixed state): -30°C – +70°C
Temperature range during installation (mobile state): -20°C – +50°C
Minimum bending radius: 7.5 x Overall Diameter

Afmetingen en het gewicht

Kabel-code

Aantal en de diameter van de draden in Dirigent

Diameter van de Ondersteunende Wire

Nominale isolatiedikte

Nominale Isolatie Diameter

Nominal Overall
Dimensions

Nominale Gewicht

Dirigent

Supporting
Wire

A

B

 

No./mm

mm/inch

mm/inch

mm/inch

mm/inch

mm/inch

mm/inch

kg/km / lbs/kft

TP7-Y-1P064-SS

2×0.64

1.2/0.047

1.00/0.039

2.65/0.104

3.20/0.125

6.1/0.24

6.1/0.24

43/28.89

TP7-Y-1P09-SS

2×0.90 1.2/0.047 1.05/0.041 3.05/0.120  3.35/0.132 8.1/0.32 6.8/0.27

52/34.94